Page 273

background image

4 Monitoring Functions

11.90

4.6 Listing of the alarms/alarm description

Alarm No.

Alarm Text:

3028

”Too many fields/variables”

Remarks:

Alarm only on commissioning

Alarm No.

Alarm Text:

3029

”Graphics option not available”

Reason:

Remedy:

Explanation:

Graphic elements have been projected into the selected display, but
the ”Graphics” option is not fitted in the control
– Retrofit ”Graphics” option
– Only project display without graphic elements
Only with additional programming developed in WS 800

Alarm-No.

Alarm Text:

3030

”Cursor memory not available”

Reason:

Remedy:
Explanation:

The cursor memory programmed for the display selected is not correct
(number not allowed or too large).
Use the workstation to redefine the cursor memory
– The function of the cursor memory is to position the cursor where it

was previously when the display is called again.

– Only with additional programming via WS 800

Alarm-No.

Alarm Text:

3032

”Too many fields / variables”

Remarks:

Alarm only on commissioning

Alarm-No.

Alarm Text:

3033

”Display text not available”

Reason:
Remedy:
Explanation:

An error has occurred while linking with the workstation.
Check link list, and relink with the workstation (to clear link error).
– Only with additional programming via WS 800
– Alarm only on commissioning

Alarm-No.

Alarm Text:

3034

”Text not available”

Explanation:

– Only with additional programming via WS 800
– Alarm only on commissioning

Alarm-No.

Alarm Text:

3040

”Fields / var. not displayable”

Explanation:

– Only with additional programming via WS 800
– Alarm only on commissioning

Alarm-No.

Alarm Text:

3041

”Too many fields / variables”

Remarks:

Alarm only on commissioning

4-30

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)