Z – z – q – x +x +q – Siemens Sinumerik 810T User Manual
Page 207
09.91
3 Operating Sequences
3.2.3 Influencing ”AUTOMATIC” operation
and
Operate the operating mode selection key on
the integrated machine control panel, and then
the ”REPOS” softkey or ...
... set the operating mode selector switch on
the external machine control panel to this
symbol.
Now switch again into the ”AUTOMATIC”
mode, using either the softkey or the
operating mode selector switch.
Program processing continues after you have pressed the “NC start” key.
The ”REPOS offset” with reference to the endpoint of the preceding block appears on the
display.
Operate the relevant direction keys.
The control guides the tool using linear
interpolation to the endpoint of the preceding
block.
or
REPOS
AUTO-
MATIC
or
+Z
– Z
– Q
– X
+X
+Q
Sequence of operation
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
3-103
SINUMERIK 810T, GA3 (BN)