Rockwell Automation 2711-ND3 PanelBuilder v2.60 Software User Manual User Manual
Page 470
Troubleshooting
F–8
Publication 2711-6.0
1. DTL_XXX TSR could not be de-installed. Issue the uninstall
command again (CFG_XXX -u).
2. An attempt was made to uninstall the DTL_XXX driver
(CFG_XXX -u) when it was not installed.
The DTL_XXX TSR could not be de-installed. Issue the uninstall
command again (CFG_XXX -u).
CFG_XXX (0011) TSR still running, unable to deinstall
The 1784-KT2 communication card must have its memory and
interrupt software configured before INTERCHANGE Software is
run. Make sure you have configured your 1784-KT2 for a memory
address and that this memory address matches that entered in the
CFG_KT.INI file.
CFG_XXX (0012) KT not found at specified ‘memory’ (KT2 only)
These errors occur during communication card diagnostics. The
execution of these diagnostics is controlled by the statement
SELFTEST=OFF in CFG_KT.INI. If this line is commented out, the
diagnostics are run by default. If this line is uncommented and says
SELFTEST=ON, the diagnostics are run. To stop the diagnostics
from running, ensure that this line is not commented out and says
SELFTEST=OFF. The most common cause for these errors is that
the software or hardware setting of the memory address for your
communication card does not match that entered into CFG_KT.INI
for the type of card you are using.
CFG_KT (0013) KT memory diagnostic RAM 0 error
CFG_KT (0014) KT memory diagnostic RAM 1 error
CFG_KT (0015) KT counter diagnostic error
CFG_KT (0016) KT timer diagnostic error
CFG_KT (0017) KT serial diagnostic error
CFG_KT (0018) KT protocol downloading error
CFG_KT (0019) KT dualport memory error
If these errors occur, contact your Rockwell Software Inc. Global
Technical Support Representative.
CFG_KT (001d) Undefined error
CFG_KT (001e) Undefined error