8–10

Creating Push Buttons

Publication 2711-6.0

Entering State Values

If Value was selected in the Write area of the Properties tab, the
Value field appears for each state.

The Value field specifies a numeric value to send to the write tag
address for each push button state. The default value for each state is
the state number (0 to 15).

The value you enter must be within the range of the Data Format
selected on the Properties tab.

Data Format

Range

Binary➀

0000 0000 0000 0000 to
1111 1111 1111 1111

Unsigned Integer

0 to 65535

Signed Integer

-32768 to +32767

4-BCD

0 to 9999

Hexadecimal➀

0 to FFFF

Octal➀

0 to 177777

➀ Formats provided for data entry. The terminal does not display or
transfer these formats.

The value is converted when a different data format is selected.