Interchange error/information messages, Interchange error/ information messages – Rockwell Automation 2711-ND3 PanelBuilder v2.60 Software User Manual User Manual
Page 468

Troubleshooting
F–6
Publication 2711-6.0
This section lists and defines errors and messages that may occur
when the INTERCHANGE Software is started or stopped. These
errors are printed to the standard output when CFG_KT.EXE,
CFG_485.EXE, CFG_DF1.EXE, or RNA.EXE are executed.
Errors and Informational Messages
from CFG_KT.EXE, CFG-485.EXE and CFG_DF1.EXE
The following errors and messages are generated by CFG_KT.EXE,
CFG_485.EXE and CFG_DF1.EXE. “XXX” represents the strings
“KT”, “485”, and “DF1”. If an error/information message is only
applicable to one of CFG_KT.EXE, CFG_485.EXE or
CFG_DF1.EXE, the applicable program will appear as the first
string of the error/information message.
These messages occur normally at startup. They indicate the
location where the INTERCHANGE Software was installed.
CFG_XXX (0000) TSR configured, no errors detected
CFG_XXX
(001A) Reading device configuration from C:\RSI\IC\BIN\CFG_KT.INI
CFG_XXX (001B) Reading diagnostic and protocol files from C:\RSI\IC\BIN
This message occurs normally at shutdown.
CFG_XXX (0001) TSR terminated, no longer resident in memory.
This message indicates an invalid version of DOS is loaded. Consult
the INTERCHANGE User Manual for valid and compatible versions
of DOS.
CFG_XXX (0002) TSR not ready, invalid version of DOS
Binary files downloaded to your communication card are
incompatible with the INTERCHANGE Software installed on your
system. Re-install the INTERCHANGE Software.
CFG_XXX (0003) TSR not configured, invalid version of KT protocol file
The indicated file could not be found. Check to ensure that the path
and/or file exist.
CFG_XXX (0004) TSR not configured, error opening file
The indicated file was found but could not be read. Check the
permissions on the file.
CFG_XXX (0005) TSR not configured, error reading file
INTERCHANGE Error/
Information Messages