Rockwell Automation 2711-ND3 PanelBuilder v2.60 Software User Manual User Manual
Page 203

12–23
Creating Bar Graphs, Indicators, Numeric Displays
Publication 2711-6.0
Editing List Text
The Text field contains the text that will appear for each entry in the
List Indicator. Double-click on the field and edit the text.
Other text fields control how the text is formatted for each state:
•
text size (the default varies for each terminal type, the selection
applies to entire list)
•
underline (default is off)
•
text blink (default is off)
•
left, right or center alignment (default is left)
•
foreground color (default is white for color and grayscale
terminals, black for monochrome terminals)
Entering State Values
If Value was selected in the Read area of the Properties tab, the Value
field appears for each state. This field defines the numeric value at
the read tag address that triggers a specific entry to be highlighted.
The range of the value you enter must be within the range of the
Data Format selected on the Properties tab. The default value for
each entry is the entry number (0 to 254).
Data Format
Range
Binary①
0000 0000 0000 0000 to 1111 1111 1111 1111
Unsigned Integer
0 to 65535
Signed Integer
-32768 to +32767
IEEE Float
-99,999,997,952 to +999,999,995,904
4-BCD
0 to 9999
Hexadecimal①
0 to FFFF
Octal①
0 to 177777
①
Formats provided for data entry. The terminal does not display/transfer these formats.