Configuring an INTERCHANGE Driver
To select and configure an INTERCHANGE driver:
1. Select a driver from the Available Drivers list.
Use the table below as a guide in selecting a driver.
The PanelView terminal type
and the communication card
installed in your computer
determines the driver selection.
For Direct Transfers Select:
For These Terminals:
To Transfer Applications:
DF1 on COM Port➀
Remote I/O, DF1, DH+,
ControlNet, DeviceNet
between the RS-232/DF1 port of a PanelView terminal and a computer using DF1
(RS232) communications.
1747-PIC
H485
RS-232 (DH-485)
between a computer and the RS-232 port of an RS-232 PanelView terminal.
1747-PIC (DH485)
on COM Port
DH-485
between a computer on the DH-485 network and the DH-485 port of a DH-485
PanelView terminal using a 1747-PIC interface converter.
➀ Driver is not required. PanelBuilder has an Internal DF1.
For Pass-Through Select:
For These Terminals:
To Transfer Applications:
Remote I/O
between a computer on the DH+ link using a 1784-KL communications card and the
Remote I/O port of a PanelView terminal on a Remote I/O network.
1784-KL on DH+
RS232 (DH-485)
between a computer on the DH+ link using a 1784-KL communications card and the
RS-232 port of a DH-485 PanelView connected to Port 0 of an SLC 5/04.
DH+
between a computer on the DH+ link using a 1784-KL communications card and the
DH+ port of a PanelView terminal on the DH+ link.
Remote I/O
between a computer on the DH+ link using a 1784-KT/B, -KT2 communications card
and the Remote I/O port of a PanelView terminal on a Remote I/O network.
1784-KT/1784-KT2 on DH+
RS-232 (DH-485)
between a computer on the DH+ link using a 1784-KT/B, -KT2 communications card
and the RS-232 port of a PanelView terminal, connected to Port 0 of an SLC 5/04.
DH+
between a computer on the DH+ link using a 1784-KT/B, -KT2 communications card
and the DH+ port of a PanelView terminal on the DH+ link.
1784-KTC on ControlNet
ControlNet
between a computer on the ControlNet network using a 1784-KTC communications
card and the ControlNet port of a PanelView terminal.
1784-KTX on DH485
DH-485
between a computer on the DH-485 network using a 1784-KTX communications
card and the DH-485 port of a PanelView terminal.