beautypg.com

Application examples, 3 filling process, 93xx – Lenze EVS9332xK User Manual

Page 369: Features, Virtual master value, Product changes possible at every clock pulse, Digital frequency output x10: virtual master value

background image

Application examples

4.3

Filling process

4−9

l

EDSVS9332K−EXT EN 4.0

+UG -UG

X4

HI

X5

93XX

X10

-

DC 24V

M

RS

3

9

+

±10V

1 X6

2

GND

LO

59

39

U

L1

1

0

L2 L3

V W

X7

A1A2A3A4

28 E1E2E3E4E5

9300kur048

Fig. 4−8

Wiring principle for the controller

0

Controller for pump drive

1

Speed setpoint

RS

Resolver

Features

l

Product−specific filling with minimum bubble generation

l

Virtual master value

l

Product changes possible at every clock pulse

l

Option: Switching point for handshake with conveyor belt

Digital signals (C0005 = 13000)

Terminal

Function

X5/28

Controller enable

X5/E1

Selection of event profile (C1420)

X5/E2

Profile selection (see table for terminal layout)

X5/E3

Profile selection (see table for terminal layout)

X5/E4

Profile selection (see table for terminal layout)

X5/E5

Error reset (TRIP reset) / profile acceptance

X5/A1

Error (TRIP)

X5/A2

Following error limit reached

X5/A3

Ready for operation (RDY)

X5/A4

Following error warning limit reached

Analog signals (C0005 = 13000)

Terminal

Function

Analog input 1: X6/1, X6/2

Setpoint of virtual master

Analog input 2: X6/3, X6/4

Not assigned

Analog output 1: X6/62

Actual speed

Analog output 2: X6/63

Actual torque

Digital frequency output X10: virtual master value

This manual is related to the following products: