Function library
Function blocks
3.2.21
Following error monitoring (CERR)
3−84
l
EDSVS9332K−EXT EN 4.0
3.2.21.3
Output of status signals
The digital outputs CERR1−ERR and CERR1−WARN indicate if the actual limit values for following
errors and following error pre−warning are exceeded or fallen below.
Enter a hysteresis under codes C1380/1 and C1380/2 to avoid instable behaviour at the change over
point.
C E R R 1 - P H I - I N
C E R R 1 - L I M
I C E R R 1 - W F A C I
1 0 0 %
C E R R 1 - L I M
C E R R 1 - E R R
C E R R 1 - W A R N
C 1 3 8 1
C 1 3 8 0
cerrerr
Fig. 3−57
Signal behaviour CERR1−ERR and CERR1−WARN
Code
Meaning
Note
C1380/1
Following error hysteresis
C1380/2
Warning hysteresis
3.2.21.4
Deactivating the output
The output of following errors and following error warnings can be deactivated with
CERR1−DISABLE = HIGH.