Following error monitoring (CERR)

3−84

l

EDSVS9332K−EXT EN 4.0

3.2.21.3

Output of status signals

The digital outputs CERR1−ERR and CERR1−WARN indicate if the actual limit values for following
errors and following error pre−warning are exceeded or fallen below.

Enter a hysteresis under codes C1380/1 and C1380/2 to avoid instable behaviour at the change over
point.

C E R R 1 - P H I - I N

C E R R 1 - L I M

I C E R R 1 - W F A C I

1 0 0 %

C E R R 1 - L I M

C E R R 1 - E R R

C E R R 1 - W A R N

C 1 3 8 1

C 1 3 8 0

cerrerr

Fig. 3−57

Signal behaviour CERR1−ERR and CERR1−WARN

Code

Meaning

Note

C1380/1

Following error hysteresis

C1380/2

Warning hysteresis

3.2.21.4

Deactivating the output

The output of following errors and following error warnings can be deactivated with
CERR1−DISABLE = HIGH.