beautypg.com

Ramp function generator for angle signals (rfgph1), Function library, Function blocks – Lenze EVS9332xK User Manual

Page 298: Range of functions

background image

Function library

Function blocks

3.2.85

Ramp function generator for angle signals (RFGPH1)

3−270

l

EDSVS9332K−EXT EN 4.0

3.2.85

Ramp function generator for angle signals (RFGPH1)

Purpose

Path or time controlled (jump) application to change position/angle (e.g. offset) relative to the master
drive.

RFGPH1

RFGPH1-IN

RFGPH1-RESET

RFGPH1-RFG-I=0

C1400/1

C1402/1

C1403/1

C1401/1

RFGPH1-T/DIST

C1400/2

C1401/3

RFGPH1-DFIN

C1404/1

C1405/1

CTRL

RFGPH1-DIST

C1402/2

C1403/2

RFGPH1-OUT

RFGPH1-IN-OLD

RFGPH1-RFG-0

C1400/3

C1401/2

fb_rfgph1

Fig. 3−221

Ramp function generator for phase signals (RFGPH1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

RFGPH1−RESET

d

1401/1

bin

1400/1

2

HIGH: Sets RFGPH1−OUT = 0 (jump)
LOW : RFGPH1−OUT is set to the value at RFGPH1−IN according to
the selected function
Input has priority over RFGPH1−RFG−0

RFGPH1−RFG−0

d

1401/2

bin

1400/2

2

HIGH : proceeds according to the selected function RFGPH1−OUT =
0
LOW : RFGPH1−OUT is set to the value at RFGPH1−IN according to
the selected function

RFGPH1−T/DIST

d

1401/3

bin

1400/3

2

Function changeover
HIGH: Path based change
LOW: Time−based change in path (position via defined speed)

RFGPH1−IN

ph

1403/1

dec [inc]

1402/1

3

Position setpoint (65536 inc. = 1 rev.)

RFGPH1−DIST

ph

1403/2

dec [inc]

1402/2

3

Path difference by which the phase is to be changed at the input
RFGPH1−IN (65536 inc. = 1 rev.)

·

Condition for accepting the value at RFGPH1−DIST:

– RFGPH1−OUT = 0

or

– the value at the RFGPH1−IN input is changing.

RFGPH1−DFIN

phd

1405/1

dec [inc]

1404/1

4

Digital frequency input
Please observe that the modes to be set for this input are selected
under C1409 (see "Phase/position to be changed through a defined
path")

RFGPH1−RFG−I=0

d

HIGH: RFGPH1−OUT = RFGPH1−IN

RFGPH1−OUT

ph

Output

RFGPH1−IN−OLD

ph

Display of the value (65536 inc. = 1 rev.) last−applied at the input
RFGPH1−IN

Range of functions

l

Change phase/position through a defined speed (chapter 3.2.85.1)

l

Change phase/position through a defined path (chapter 3.2.85.2)

l

Output of status signals (chapter 3.2.85.3)

This manual is related to the following products: