beautypg.com

70 oscilloscope function (osz), Oscilloscope function (osz), Function library – Lenze EVS9332xK User Manual

Page 258: Function blocks, Function the fb has three function units

background image

Function library

Function blocks

3.2.70

Oscilloscope function (OSZ)

3−230

l

EDSVS9332K−EXT EN 4.0

3.2.70

Oscilloscope function (OSZ)

Purpose

Detection of any measured variable (e. g. speed setpoint, actual speed, torque etc.). They are
visualised in Global Drive Control.

Supports the commissioning of controllers and the troubleshooting.

OSZ-CHANNEL1

OSZ

OSZ-DIG-TRIGGER

C0734

C0735

C0737

C0730

C0731

C0736

C0739

C0749

C0744

C0738

C0740

C0741

measuring

value

memory

1

2

3
4

CTRL

OSZ-CHANNEL2
OSZ-CHANNEL3
OSZ-CHANNEL4

C0733/1

C0732/1

C0732/2

C0732/3

C0732/4

fb_osz

Fig. 3−182

Oscilloscope function (OSZ)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

OSZ CHANNEL1

a

C0732/1

1

OSZ CHANNEL2

a

C0732/2

1

OSZ CHANNEL3

a

C0732/3

1

OSZ CHANNEL4

a

C0732/4

1

OSZ−DIG−TRIGGER

d

C0733/1

2

Function

The FB has three function units:

l

Trigger check

– Monitoring of the digital trigger source for a valid trigger event

l

Processing of the measured signal

– Linking the measurement inputs

– Calculating the time base

– Monitoring of the analog trigger source for a valid trigger event.

l

Measuring value memory

– Scaling the ring buffer

– Filing the measured data in the ring buffer

– Saving the measuring points for image generation