31 conversion of stretch factor (convphd), Conversion of stretch factor (convphd), Function library – Lenze EVS9332xK User Manual
Page 148: Function blocks, Stop
Function library
Function blocks
3.2.31
Conversion of stretch factor (CONVPHD)
3−120
l
EDSVS9332K−EXT EN 4.0
3.2.31
Conversion of stretch factor (CONVPHD)
One function block (CONVPHD1) is available.
Purpose
l
Exact adaptation of the incremental encoder
l
CONVPHD1 for the adjustment of the stretch factor via freely configurable inputs
Y
X
C 1 4 8 6 / 1
C 1 4 8 7 / 1
C 1 4 8 8 / 1
C 1 4 8 9 / 1
C 1 4 8 6 / 2
C 1 4 8 7 / 2
C O N V P H D 1 - N O M
C O N V P H D 1 - I N
C O N V P H D 1 - D E N
C 1 4 8 0
C O N V P H D 1
C O N V P H D 1 - O U T
± 1 9 6 5 r p m
Signal
Source
Note
Name
Type
DIS/selection
DIS format
CFG
List
CONVPHD1−DEN
ph
1487/2
dec [inc]
1486/2
3
Stretch factor denominator, input limited to
+1 to +200000000
CONVPHD1−IN
phd
1489/1
dec [inc]
1488/1
4
The input is limited to
±1965 rpm
CONVPHD1−NOM
ph
1487/1
dec [inc]
1486/1
3
Stretch factor numerator, input limited to
±1 to ±200000000
CONVPHD1−OUT
phd
−
−
−
Output in rpm
Function
l
Function block interconnection
l
Encoder settings increments of one
l
Stretch factor setting over 6 decades
3.2.31.1
Function block interconnection
The function block is connected directly after the digital frequency input DFIN.
STOP!
The DFIN code C0425 must be set to selection 6 to evaluate the encoder signals correctly.