beautypg.com

31 conversion of stretch factor (convphd), Conversion of stretch factor (convphd), Function library – Lenze EVS9332xK User Manual

Page 148: Function blocks, Stop

background image

Function library

Function blocks

3.2.31

Conversion of stretch factor (CONVPHD)

3−120

l

EDSVS9332K−EXT EN 4.0

3.2.31

Conversion of stretch factor (CONVPHD)

One function block (CONVPHD1) is available.

Purpose

l

Exact adaptation of the incremental encoder

l

CONVPHD1 for the adjustment of the stretch factor via freely configurable inputs

Y

X

C 1 4 8 6 / 1

C 1 4 8 7 / 1

C 1 4 8 8 / 1

C 1 4 8 9 / 1

C 1 4 8 6 / 2

C 1 4 8 7 / 2

C O N V P H D 1 - N O M

C O N V P H D 1 - I N

C O N V P H D 1 - D E N

C 1 4 8 0

C O N V P H D 1

C O N V P H D 1 - O U T

± 1 9 6 5 r p m

Signal

Source

Note

Name

Type

DIS/selection

DIS format

CFG

List

CONVPHD1−DEN

ph

1487/2

dec [inc]

1486/2

3

Stretch factor denominator, input limited to
+1 to +200000000

CONVPHD1−IN

phd

1489/1

dec [inc]

1488/1

4

The input is limited to

±1965 rpm

CONVPHD1−NOM

ph

1487/1

dec [inc]

1486/1

3

Stretch factor numerator, input limited to

±1 to ±200000000

CONVPHD1−OUT

phd

Output in rpm

Function

l

Function block interconnection

l

Encoder settings increments of one

l

Stretch factor setting over 6 decades

3.2.31.1

Function block interconnection

The function block is connected directly after the digital frequency input DFIN.

STOP!

The DFIN code C0425 must be set to selection 6 to evaluate the encoder signals correctly.

This manual is related to the following products: