1 changing the basic configuration, Changing the basic configuration, Configuration – Lenze EVS9332xK User Manual
Page 19

Configuration
Basic configurations
2.2.1
Changing the basic configuration
2−5
l
EDSVS9332K−EXT EN 4.0
Profile data
Before commissioning, the profile data must be generated with the Global Drive Control program and
the transmitted to the drive. The below basic cam profiles are included in the Lenze setting. They are
effective independently of the basic parameter setting.
Profile 1
Electronic gearbox (linear position profile)
Profile 2
Forward / backward movement with a standstill in the apex of the motion
Profile 3
Forward / backward movement with a standstill at the end of motion
Profile 4
Smooth feed
Profiles 5 − 8
No motion
}
Warning!
With Lenze setting, the motor must be operated at no−load (no mechanical
connection to the machine).
2.2.1
Changing the basic configuration
If the basic configuration must be changed for a special application, proceed as follows:
1. Select a basic configuration via C0005 which largely meets the requirements.
2. Add functions by:
– Reconfiguring inputs and/or outputs.
– Setting parameters for function blocks. (
^ 3−6
)
– Inserting or removing function blocks. (
^ 3−12
)
)
Note!
If you change the signal flow of the basic configuration, e. g. by adding function
blocks, C0005 is set to 0. The display indicates "COMMON".