88 angle value selection (selph), Angle value selection (selph), Function library – Lenze EVS9332xK User Manual
Page 310: Function blocks

Function library
Function blocks
3.2.88
Angle value selection (SELPH)
3−282
l
EDSVS9332K−EXT EN 4.0
3.2.88
Angle value selection (SELPH)
Two FBs (SELPH1, SELPH2) are available.
Purpose
Select one angle value from nine angle values and switch it to the output.
SELPH1
SELPH1-IN1
SELPH1
C1662/1
C1664/1
SELPH1-OUT
SELPH1-SELECT
C1661
C1663
SELPH1-IN2
C1662/2
C1664/2
SELPH1-IN3
C1662/3
C1664/3
SELPH1-IN4
C1662/4
C1664/4
SELPH1-IN5
C1662/5
C1664/5
SELPH1-IN6
C1662/6
C1664/6
SELPH1-IN7
C1662/7
C1664/7
SELPH1-IN8
C1662/8
C1664/8
FIXED0INC
1
2
3
4
5
6
7
8
0
8
C1660
0
Fig. 3−228
Function block SELPH1
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
SELPH1−SELECT
a
C1663
dec
C1661
1
−
SELPH1−IN1
ph
C1664/1
dec [inc]
C1662/1
3
−
SELPH1−IN2
ph
C1664/2
dec [inc]
C1662/2
3
−
SELPH1−IN3
ph
C1664/3
dec [inc]
C1662/3
3
−
SELPH1−IN4
ph
C1664/4
dec [inc]
C1662/4
3
−
SELPH1−IN5
ph
C1664/5
dec [inc]
C1662/5
3
−
SELPH1−IN6
ph
C1664/6
dec [inc]
C1662/6
3
−
SELPH1−IN7
ph
C1664/7
dec [inc]
C1662/7
3
−
SELPH1−IN8
ph
C1664/8
dec [inc]
C1662/8
3
−
SELPH1−OUT
ph
−
−
−
−
−
−
−
C1660
dec
−
−
Displays the current selection