beautypg.com

39 dead band (db), Dead band (db), Function library – Lenze EVS9332xK User Manual

Page 164: Function blocks

background image

Function library

Function blocks

3.2.39

Dead band (DB)

3−136

l

EDSVS9332K−EXT EN 4.0

3.2.39

Dead band (DB)

Purpose

The dead band element is used to set interfering influences around zero, e.g. interferences on analog
input voltages, to digital zero.

D B 1

D B 1 - O U T

D B 1 - I N

C 0 6 2 3

C 0 6 2 2

± 1 9 9 , 9 9 %

C 0 6 2 1

C 0 6 2 0

Fig. 3−101

Dead band element (DB1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

DB1−IN

a

C0623

dec [%]

C0622

1

1000

DB1−OUT

a

Limited to ±199.99 %

Function

l

The dead band is parameterised under C0621.

l

The gain is set under C0620.

C0621

C0620

DB1−IN

DB1−OUT

Fig. 3−102

Dead band and gain