Function library

Function blocks

3.2.93

Storage block (STORE1)

3−296

l

EDSVS9332K−EXT EN 4.0

Outputting the difference of the two angle signals saved

l

A two−stage counter controls the output at STORE1−PHDIFF.

l

Every second triggering via the TP input E5 results in a new output at STORE1−PHDIFF.

l

STORE1−LOAD0 = HIGH resets the counter.

Additional control

1. STORE1−LOAD1 = LOW−HIGH edge resets the counter to the 1st stage (preparation of the

output at STORE1−PHDIFF).

2. Triggering via the TP input E5 sets the counter to the 2nd stage (output at STORE1−PHDIFF is

effected).

)

Note!

If STORE1−LOAD1 is set cyclically, STORE1−PHDIFF outputs a new differential
signal after each triggering process.