Function library, Function blocks, Conv4 – Lenze EVS9332xK User Manual
Page 138: Conv5
Function library
Function blocks
3−110
l
EDSVS9332K−EXT EN 4.0
CONV4
C O N V 4
C O N V 4 - O U T
C O N V 4 - I N
C 0 9 5 8
C 0 9 5 7
C 0 9 5 5
C 0 9 5 6
C O N V 4 - D F O U T
Fig. 3−81
Function block CONV4
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CONV4−IN
phd
C0958
dec [rpm]
C0957
4
1000
CONV4−OUT
a
−
−
−
−
−
Limited to ±199.99 %
CONV4−DFOUT
phd
−
−
−
−
−
Limited to ±29999 rpm
This function block is used to convert speed signals into analog signals.
Conversion according to formula:
CONV4−OUT
+ CONV4−IN @
100 %
15000 rpm
@ C0955
C0956
or
CONV4−DFOUT
+ CONV3−IN @ C0955
C0956
[rpm]
CONV5
CONV5
CONV5-OUT
CONV5-IN
C0658
C0657
C0655
C0656
Fig. 3−82
Function block CONV5
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CONV5−IN
a
C0658
dec [%]
C0657
1
1000
CONV5−OUT
phd
−
−
−
−
−
Limited to ±29999 rpm
This function block is used to convert analog signals into speed signals.
Conversion according to formula:
CONV5−OUT
+ CONV5−IN @
15000 rpm
100 %
@ C0655
C0656