Function library, Function blocks – Lenze EVS9332xK User Manual
Page 273

Function library
Function blocks
3.2.76
Angle integrator (PHINT1, PHINT2, PHINT3)
3−245
l
EDSVS9332K−EXT EN 4.0
C1150 = 0
C1150 = 1
The input PHINT3−LOAD is state−triggered (HIGH level).
·
PHINT3−LOAD = HIGH
– The integrator is loaded with the input value at PHINT3−SET.
– Sets the output PHINT3−STATUS = LOW
The input PHINT3−LOAD is edge−triggered (LOW−HIGH edge).
·
PHINT3−LOAD = LOW−HIGH edge
– The integrator is loaded with the input value at PHINT3−SET
and starts adding from this point
– Sets the output PHINT3−STATUS = LOW
P H I N T 3 - O U T
+ 3 2 7 6 7 r e v .
- 3 2 7 6 7 r e v .
+ C 1 1 5 1
- C 1 1 5 1
t
t
P H I N T 3 - S T A T U S
Fig. 3−200
Function of PHINT3 with constant input value when C1150 = 0 and C1150 = 1
l
The FB integrates speed or velocity values at PHINT3−IN to a angle (distance).
l
PHINT3−OUT outputs the counter content of the bipolar integrator.
– A positive value at PHINT3−IN increments the integrator (counter content is increased).
– A negative value at PHINT3−IN decrements the integrator (counter content is reduced).
l
If the counter content exceeds the value of +32767 encoder revolutions (
¢ +2147483647 inc)
– an overflow occurs. The counting is continued with the value −32768,
– PHINT3−STATUS switches to HIGH when the value (+) C1151 is reached
l
If the counter content falls below the value of −32768 encoder revolutions
(
¢ −2147483648 inc)
– an overflow occurs. The counting starts at the value +32767,
– PHINT3−STATUS switches to HIGH when the value (−) C1151 is reached