Function library, Function blocks, 2 change phase/position through a defined path – Lenze EVS9332xK User Manual

Page 300: Wiring of the inputs, Master value at rfgph1−dfin

background image

Function library

Function blocks

3.2.85

Ramp function generator for angle signals (RFGPH1)

3−272

l

EDSVS9332K−EXT EN 4.0

3.2.85.1

Change phase/position through a defined speed

Inputs for parameter setting:

l

FCODE C1476/1 = 5 m−units (position)

l

C1408/1 = 200.0 rpm: the drive travels to the target position with a master value speed of
200 rpm.

Control:

l

X5/E1 = HIGH: CDATA−XOFFS is traversed to 5 m−units at n = 200 rpm

l

X5/E1 = LOW: CDATA−XOFFS is traversed to 0 m−units at n = 200 rpm

l

The time required to reach the position results from the physical parameters selected.

t

t

RFGPH1−RFG−0

RFGPH1−IN

RFGPH1−OUT

C1408/1

C1408/1

C1408/1

3.2.85.2

Change phase/position through a defined path

RFGPH1

RFGPH1-IN

RFGPH1-RESET

RFGPH1-RFG-I=0

C1400/1

C1402/1

C1403/1

C1401/1

RFGPH1-T/DIST

C1400/2

C1401/3

RFGPH1-DFIN

C1404/1

C1405/1

CTRL

RFGPH1-DIST

C1402/2

C1403/2

RFGPH1-OUT

RFGPH1-IN-OLD

RFGPH1-RFG-0

C1400/3

C1401/2

CDATA-XOFFS

C1476/1

FCODE

FIXED0

DFIN-OUT

C1476/2

FCODE

9300kur026

Wiring of the inputs:

l

FCODE C1476/2 = 10 m−units (=RFGPH1−DIST)

l

FCODE C1476/1 = 2.5 m−units (=RFGPH1−IN)

l

Master value at RFGPH1−DFIN.