beautypg.com

Function library, Function blocks, Stop – Lenze EVS9332xK User Manual

Page 185

background image

Function library

Function blocks

3.2.44

Digital frequency processing (DFSET)

3−157

l

EDSVS9332K−EXT EN 4.0

Stop!

When the synchronisation via the terminals X5/E4 and X5/E5 (C0532 = 2) is activated, no further
control signals must be taken from these terminals. Changing the configuration via C0005 assigns
the terminals with a basic setting.

Synchronisation mode

For the synchronisation, different modes are available which can be set under C0534.

C0534

Synchronisation mode

Note

0

Inactive

Function inactive

1

Continuous synchronisation with correction in the shortest
possible way

2

Continuous synchronisation with correction in the shortest
possible way

after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out continuously if a HIGH level remains at
DFSET−0−Pulse.

10

One synchronisation, a phase deviation is corrected in the
shortest possible way

after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out once

11

One synchronisation, a phase deviation is corrected in CW
direction

after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out once

12

One synchronisation, a phase deviation is corrected in CCW
direction

after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out once

13

Single synchronisation, a phase difference is determined between
setpoint pulse and actual pulse and is corrected to the
corresponding direction of rotation according to the sign

after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out once

Code C0528/1 displays the number of increments (angular difference) between the setpoint pulse
and the actual pulse prior to synchronisation.

Code C0528/2 displays the offset value from (C0523 x C0529 + C0252).