Function library, Function blocks, Stop – Lenze EVS9332xK User Manual
Page 185

Function library
Function blocks
3.2.44
Digital frequency processing (DFSET)
3−157
l
EDSVS9332K−EXT EN 4.0
Stop!
When the synchronisation via the terminals X5/E4 and X5/E5 (C0532 = 2) is activated, no further
control signals must be taken from these terminals. Changing the configuration via C0005 assigns
the terminals with a basic setting.
Synchronisation mode
For the synchronisation, different modes are available which can be set under C0534.
C0534
Synchronisation mode
Note
0
Inactive
Function inactive
1
Continuous synchronisation with correction in the shortest
possible way
2
Continuous synchronisation with correction in the shortest
possible way
after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out continuously if a HIGH level remains at
DFSET−0−Pulse.
10
One synchronisation, a phase deviation is corrected in the
shortest possible way
after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out once
11
One synchronisation, a phase deviation is corrected in CW
direction
after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out once
12
One synchronisation, a phase deviation is corrected in CCW
direction
after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out once
13
Single synchronisation, a phase difference is determined between
setpoint pulse and actual pulse and is corrected to the
corresponding direction of rotation according to the sign
after a LOW−HIGH edge at DFSET−0−Pulse, synchronisation is
carried out once
Code C0528/1 displays the number of increments (angular difference) between the setpoint pulse
and the actual pulse prior to synchronisation.
Code C0528/2 displays the offset value from (C0523 x C0529 + C0252).