3.2.70

Oscilloscope function (OSZ)

3−231

l

EDSVS9332K−EXT EN 4.0

Functional description

Function

Code

Selection

Description

OSZ mode

Controls the measurement in the controller

C0730

1

·

Starts the recording of the measured values

0

·

Cancels a running measurement

OSZ status

Displays five different operating states

C0731

1

·

Measurement completed

– The memory of the measured values is completely filled with measured data. The

measured values can be accessed via the PC.

2

·

Measurement active

– A measurement was started with C0730 = 1. The FB is waiting for a valid trigger

event.

3

·

Trigger detected

– The FB has detected a valid trigger event. Depending on the trigger delay the

saving of the measured data is not yet completed. It is automatically completed
with the entry into the last memory unit.

4

·

Measurement cancelled

– Cancel of a running recording of the measured values (C0730 = 0). The memory of

the measured values is filled with the data that has just been measured. The data
can be accessed via the PC.

5

·

Read data memory

– The measured data memory is being read at the moment. No settings are possible

in this operating state.

Configuration
OSZ channel
1 ... 4

C0732/1
to
C0732/4

·

Links the measuring channels of the FB with the signals of the process environment

– The four measuring channels can be assigned with any analog signal. Enter the

corresponding signal number into C0732/1 ... C0732/4.

– Always start linking with channel 1, then channel 2 and so on. Unused channels

are automatically assigned with signal FIXED 0%.

Configuration
OSZ trigger

C0733/1

Links the digital trigger input with a digital signal in the process environment.

– The trigger input can be assigned with any digital signal. Enter the corresponding

signal number into C0733/1.

Trigger source

Defines the trigger source

C0734

1

Source is one of the four measuring channels (C0734/1 ... C0734/4)

0

Source is the digital trigger input (C0733/1)

Trigger level

C0735

−32767 ... 32767

·

Defines the trigger level which activates the triggering when the level is exceeded.

– The trigger level is only monitored when the triggering is done on one of the four

channels.

– The trigger level is not effective with digital triggering.

Trigger edge

Defines the trigger edge which activates the triggering.

·

Triggering on an analog input channel

– With a LOW−HIGH trigger edge the analog trigger signal must exceed a defined

trigger level to activate the triggering.

– With a HIGH−LOW trigger edge the analog trigger signal must fall below a defined

trigger level to activate the triggering.

·

Triggering on a digital trigger input

– With a LOW−HIGH trigger edge the digital trigger signal must change from LOW to

HIGH to activate the triggering.

– With a HIGH−LOW trigger edge the digital trigger signal must change from HIGH to

LOW to activate the triggering.

Fig. 3−183 shows the triggering of an analog signal with a positive edge.

C0736

1

HIGH−LOW trigger edge

0

LOW−HIGH trigger edge