46 freely assignable digital inputs (digin), Freely assignable digital inputs (digin), Function library – Lenze EVS9332xK User Manual
Page 189: Function blocks
Function library
Function blocks
3.2.46
Freely assignable digital inputs (DIGIN)
3−161
l
EDSVS9332K−EXT EN 4.0
3.2.46
Freely assignable digital inputs (DIGIN)
Purpose
Reading and conditioning of the signals at the terminals X5/E1 to X5/E5.
E1
E2
E3
E4
E5
1
0
C0114/1...5
DIGIN
DIGIN1
DIGIN2
DIGIN3
DIGIN4
DIGIN5
C0443
28
DCTRL -X5/28
X5
DIGIN-CINH
1
Fig. 3−123
Freely assignable digital inputs (DIGIN)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
DIGIN−CINH
d
−
dec
−
−
−
Controller inhibit acts directly on the DCTRL
control
DIGIN1
d
C0443
dec
−
−
−
−
DIGIN2
d
C0443
dec
−
−
−
−
DIGIN3
d
C0443
dec
−
−
−
−
DIGIN4
d
C0443
dec
−
−
−
−
DIGIN5
d
C0443
dec
−
−
−
−
Function
The terminals X5/E1 to X5/E5 are scanned every millisecond. The level for every input can be
inverted. For this, proceed as follows:
l
Select code C0114 with corresponding subcode (e.g. subcode 3 for input X5/E3)
l
Enter the desired level as a parameter:
– 0 = Level not inverted (HIGH active)
– 1 = Level inverted (LOW active)