3.2.24

Clutch (CLUTCH 3)

3−98

l

EDSVS9332K−EXT EN 4.0

Function sequence

T A R G E T - P O S

B r a k e - P o s i t i o n

v e l o c i t y

0

C L O S E

N S E T

t

t

P H O U T

t

L E N

T A R G E T - P O S

B r a k e - P o s i t i o n

O P E N

t

A C C / D E C

t

C 1 7 0 6 / 2

t i

P H I - S E T

t i

fb_clutch3_12

Fig. 3−67

Angle diagram and path−time diagram: Time−controlled disengaging in target position

0

External master angle at CLUTCH3−PHI−SET

1

Internal master angle at CLUTCH3−PHI−ACT

PHI−SET

Position of the external master angle at CLUTCH3−PHI−SET after completion of the disengaging process

TARGET−POS Target position specified at CLUTCH3−TARGET−POS
OPEN

If CLUTCH3−OPEN switches to HIGH, the clutch is disengaged

ACC/DEC

During the disengaging process, CLUTCH3−ACC/DEC = HIGH

l

The internal master angle (PHOUT) synchronically follows the master value to the brake
position. At the brake position the braking process is started.

– The brake position is automatically calculated from the deceleration time Ti.

– The brake position is variable and depends on the current machine speed.

l

If the target position is reached, the braking process is completed.

l

If CLUTCH3−LOW−VEL = 0, the internal master angle (PHOUT) is 0 at the target position.

Adjustment

l

Set C1707 = 0.

l

Define the target position at CLUTCH3−TARGET−POS.

l

Set the deceleration time Ti [s] in C1706/2.

l

Define the external master angle at CLUTCH3−PHI−SET.