Configuration, Basic configurations, 3 basic configurations 1x2xx: clutch function – Lenze EVS9332xK User Manual
Page 21
Configuration
Basic configurations
2.2.2
Basic configuration C0005 = 1xXxx
2−7
l
EDSVS9332K−EXT EN 4.0
2.2.2.3
Basic configurations 1x2xx: Clutch function
x
x
Clutch function
Engage clutch
(CLUTCH)
C0472/2
C0472/3
Overload limt
value
C1477/5
Profile control
(CCTRL)
C1477/2
Following error
Motor control
C0472/4
(CERR1)
C1380/1,2
(-1)
C0006, C0011,
C0022, C0070,
C0071, C0086,
C0105, C0254
(MCTRL)
9300kur081
Fig. 2−2
Section of the signal flow diagram showing the basic configuration 1X2XX with clutch function
Function
Digital inputs
X5/28
Controller enable
X5/E1
Event profile
X5/E2
Profile *1
X5/E3
Profile *2
X5/E4
Engage clutch
X5/E5
Trip reset / profile acceptance
Digital outputs
X5/A1
TRIP
X5/A2
Contouring error
X5/A3
RDY
X5/A4
Clutch disengaged
Analog inputs
X6/1, X6/2
–
X6/3, X6/4
–
Analog outputs
X6/62
Actual speed value
X6/63
Actual torque value
Additional code
C1477/5
Home position
Parameters of FB CLUTCH
C1410
Clutch mode
C1411
Max. velocity
C1412/1
Ramp opening time
C1412/2
Ramp profile generator
C1412/3
Overload time delay
C1413
Catch hysteresis