beautypg.com

Function library – Lenze EVS9332xK User Manual

Page 323

background image

Function library

Function blocks

3.2.93

Storage block (STORE1)

3−295

l

EDSVS9332K−EXT EN 4.0

Function

l

Control via TP input X5/E5

l

Saving the angle signal

3.2.93.1

Control via TP input X5/E5

The triggering signal STORE1−TP−INH indicates by means of a HIGH signal a triggering effected via
the TP input E5 (LOW−HIGH edge on X5/E5). At the same time STORE1−TP−INH signalises that the
triggering is deactivated and has to be reset to the active state. This can be effected via

l

STORE1−RESET = HIGH

l

STORE1−ENTP = LOW−HIGH edge

l

STORE1−ENWIN = HIGH and the comparison of angle signals

Comparison of angle signals

The speed signal on STORE1−MASKI is integrated to a angle signal and is compared to the angle
signal on STORE1−MASKV.

If the condition | STORE1−MASKI |

w STORE1−MASKV

is met,

l

the TP input E5 is enabled for the next triggering process with STORE1−ENWIN = HIGH,

l

the integrator for the speed signal on STORE1−MASKI is reset.

3.2.93.2

Saving the angle signal

A speed signal at input STORE1−IN is integrated to a angle signal. In addition to the saving, the
following procedure shows the possibilities for the signal output.

l

The current angle signal is output at STORE1−ACT.

1. A LOW−HIGH edge at the TP input E5 saves the last angle signal and outputs it at

STORE1−PH1.

2. STORE1−ENTP = LOW−HIGH edge enables the TP input E5 for the next triggering process.

3. A new LOW−HIGH edge at the TP input E5 saves the last angle signal.

– STORE1−PH1 outputs this last angle signal.

– STORE1−PH2 outputs the next to last angle signal.

– STORE1−PHDIFF outputs the difference of STORE1−PH1 and STORE1−PH2.

l

STORE1−RESET = HIGH resets the memory, counters, and integrators and enables the TP
input E5 for the triggering process.