Function library

Function blocks

3.2.34

Conversion (CONVPHPHD2)

3−125

l

EDSVS9332K−EXT EN 4.0

(

STOP!

The function block can evaluate signal jumps at the input CONVPHPHD2−IN up to
max. 2147483647 inc (2

31

−1). At higher signal jumps the sign of the output signal

changes.

A position loss occurs which cannot be compensated anymore. You must carry out
a reset (CONVPHPHD2−RESET = HIGH).

0

1

-1

2 147 483 647 (2 -1)

31

-2 147 483 648 (-2 )

31

-2 147 483 647 (-2 +1)

31

1073741824 (2 /2)

31

-1073741824 (-2 /2)

31

Fig. 3−94

32−bit data representation in the cycle of numbers

Example 1

1. The input signal at CONVPHPHD2−IN is 65536 inc.
2. Now it jumps to −65536 inc.
3. The output CONVPHPHD2−OUT outputs, as expected, negative values

Example 2

1. The input signal at CONVPHPHD2−IN is 65536 inc.
2. Now it jumps to −2

31

−1 inc.

3. The output CONVPHPHD2−OUT, however, outputs positive values