Function library
Function blocks
3.2.43
Digital frequency ramp function generator (DFRFG)
3−150
l
EDSVS9332K−EXT EN 4.0
3.2.43.2
Quick stop
Removes the drive from the network and brakes it to standstill.
l
Activate with DFRFG−QSP = HIGH.
l
Set deceleration time via C0753.
l
Store the setpoint phase detected at DFRFG−IN.
l
Approach the setpoint phase via the profile generator after resetting the quick stop request.
t
DFRFG-IN
C0752
C0751
C0751
DFRFG-QSP
t
DFRFG-OUT
C0753
Fig. 3−114
Quick stop DFRFG
3.2.43.3
Ramp function generator stop
Maintains the state of the profile generator during operation.
l
Activate with DFRFG−STOP = HIGH
l
Output of the last state at DFRFG−OUT.
l
Store the setpoint phase detected at DFRFG−IN.
l
Approach the setpoint phase via the profile generator after resetting the stop request.
t
DFRFG-IN
C0752
DFRFG-STOP
t
DFRFG-OUT
Fig. 3−115
Ramp function generator stop