91 output of digital status signals (stat), Output of digital status signals (stat), Function library – Lenze EVS9332xK User Manual
Page 320: Function blocks
Function library
Function blocks
3.2.91
Output of digital status signals (STAT)
3−292
l
EDSVS9332K−EXT EN 4.0
3.2.91
Output of digital status signals (STAT)
Purpose
The FB evaluates digital signals of function blocks and the status of the controller and passes them
on to C0150 and FB AIF−OUT and CAN−OUT1.
C0156/1 STAT.B0
STAT.B2
STAT.B3
STAT.B4
STAT.B5
STAT.B14
STAT.B15
DCTRL-IMP
STAT
DCTRL-WARN
DCTRL-MESS
DCTRL-NACT=0
C0156/2
C0156/3
C0156/4
C0156/5
DCTRL-STAT*1
DCTRL-STAT*2
DCTRL-STAT*4
DCTRL-STAT*8
0
1
2
3
4
5
6
8
9
DCTRL-CINH
7
10
11
12
13
14
15
C0156/6
C0156/7
AIF-
Statusword
C0150
CAN1-
Statusword
Fig. 3−240
Output of digital status signals (STAT)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
STAT.B0
d
−
bin
C0156/1
2
2000
STAT.B2
d
−
bin
C0156/2
2
5002
STAT.B3
d
−
bin
C0156/3
2
5003
STAT.B4
d
−
bin
C0156/4
2
5050
STAT.B5
d
−
bin
C0156/5
2
10650
STAT.B14
d
−
bin
C0156/6
2
505
STAT.B15
d
−
bin
C0156/7
2
500
Function
The status word consists of some fixedly linked (DCTRL−xxxx−) and some freely linkable signal inputs
(STAT.Bx).
l
Digital signal sources can be freely assigned to the inputs STAT.Bx.
l
The corresponding bit in the data word is marked with STAT.Bx (e.g. STAT.B0 for the LSB)
l
The status word is transferred to code C0150 and to the function blocks AIF−OUT and
CAN−OUT1.
l
The inputs with the name DCTRL−xxxx are directly accepted from the function block DCTRL.
(