beautypg.com

Function library, Function blocks – Lenze EVS9332xK User Manual

Page 120

background image

Function library

Function blocks

3.2.24

Clutch (CLUTCH 3)

3−92

l

EDSVS9332K−EXT EN 4.0

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

CLUTCH3−OPEN−INSTANT

d

C1701/1

bin

C1700/1

2

HIGH: Disengage immediately, reset fault messages

CLUTCH3−CLOSE

d

C1701/3

bin

C1700/3

2

HIGH: Close clutch
LOW: Open clutch

CLUTCH3−TARGET−POS

ph

C1703/1

dec [inc]

C1702/1

3

Specification of the target position

CLUTCH3−DIST

ph

C1703/2

dec [inc]

C1702/2

3

Reserved

CLUTCH3−PHI−SET

ph

C1703/3

dec [inc]

C1702/3

3

Setpoint position of the external master angle

CLUTCH3−PHI−ACT

ph

C1703/4

dec [inc]

C1702/4

3

Actual position of the internal master angle

CLUTCH3−LEN

ph

C1703/5

dec [inc]

C1702/5

3

Clock pulse length (X axis)

CLUTCH3−LOW−VEL

phd

C1705/1

dec [rpm]

C1704/1

4

Specification of a minimum speed with which the
internal master angle is to rotate after disengaging

CLUTCH3−OPEN

d

2

HIGH: Clutch disengaged
LOW: Clutch engaged

CLUTCH3−ACC/DEC

d

2

HIGH: Signal at CLUTCH3−PHOUT and CLUTCH3−NSET
is accelerated
LOW: Signal at CLUTCH3−PHOUT and CLUTCH3−NSET
is decelerated

CLUTCH3−DIR−ERR

d

2

HIGH: The input signals at CLUTCH3−PHI−SET and
CLUTCH3−PHI−ACT have an opposite direction of
rotation

CLUTCH3−INIT

d

2

Reserved

CLUTCH3−ERR

d

2

General error message from CLUTCH3

·

HIGH: The process of engaging the clutch has been
started although the disengaging process had not
yet been completed.

·

The value 0 is applied at CLUTCH3−LEN.

CLUTCH3−VEL−TO−LOW

d

2

HIGH: The process of engaging the clutch cannot be
carried out, as the speed at CLUTCH3−PHI−SET is
< 4 min

−1

CLUTCH3−ACT−SET

ph

3

Differential signal between CLUTCH3−ACT−SET and
CLUTCH3−PHI−SET if CLUTCH3−CLOSE is set = HIGH

·

The differential signal corresponds to the distance
of the internal master angle still be compensated
until it runs synchronously with the external master
angle.

CLUTCH3−PHOUT

ph

3

Output of the internal master angle position

·

The signal refers to one machine clock pulse
(CLUTCH3−LEN)

·

The signal can be linked to CDATA−XIN.

·

If the clutch is engaged, the external and internal
master angles are running synchronously.

CLUTCH3−NSET

phd

4

Speed setpoint

Function

l

Important notes (

3−93)

l

Fault messages (

3−93)

l

Disengage immediately (

3−93)

l

Minimum speed after disengaging (

3−94)

l

Time−controlled engaging (

¶ 3−95)

l

Selection of the disengaging position (

3−96)

l

Selection of the target position in the disengaged state (

¶ 3−97)

l

Time−controlled disengaging in target position (

¶ 3−97)

l

Time−controlled disengaging at the disengaging position (

3−99)

l

Engaging the clutch at different positions of the external master angle (

¶ 3−100)

l

Time−controlled engaging (

¶ 3−102)

This manual is related to the following products: