33 conversion (convphphd1), Conversion (convphphd1), Function library – Lenze EVS9332xK User Manual
Page 151: Function blocks

Function library
Function blocks
3.2.33
Conversion (CONVPHPHD1)
3−123
l
EDSVS9332K−EXT EN 4.0
3.2.33
Conversion (CONVPHPHD1)
A angle change is converted into a speed (digital frequency).
C 1 4 5 1 / 1
C O N V P H P H D 1
C O N V P H P H D 1 - I N
C O N V P H P H D 1 - O U T
C 1 4 5 3
C 1 4 5 2
C 1 4 5 0 / 1
C O N V P H P H D 1 - F A I L
x
y
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
CONVPHPHD1−IN
ph
1451/1
dec [inc]
1450/1
3
Angle input (ref.: 65536 inc = 1 motor revolution)
CONVPHPHD1−FAIL
d
−
−
−
HIGH: Resulting speed > 30000 rpm
CONVPHPHD1−OUT
phd
−
−
−
Output in rpm
Function
An angle change at input CONVPHPHD1−IN is converted into a speed.
l
The speed at the output CONVPHPHD1−OUT can be adapted by means of a division ratio.
The numerator (C1452) and denominator (C1453) can be set between −32767 and +32767.
l
The output is limited to
±n = 30000 rpm.
l
CONVPHPHD1−FAIL = HIGH for the time of limitation.
Note!
Angle errors can occur in the following function blocks if the output is limited. The profile position can
thus be lost.