beautypg.com

22 virtual clutch (clutch1), Virtual clutch (clutch1), Function library – Lenze EVS9332xK User Manual

Page 113: Function blocks, Function

background image

Function library

Function blocks

3.2.22

Virtual clutch (CLUTCH1)

3−85

l

EDSVS9332K−EXT EN 4.0

3.2.22

Virtual clutch (CLUTCH1)

Purpose

Engagement and disenConnection and disengagement of the X or Y axis.

C L U T C H - N S E T

C L U T C H - M L I M

C 1 4 1 4 / 1

C 1 4 1 5 / 1

C L U T C H - M - A C T

C 1 4 1 4 / 2

C 1 4 1 5 / 2

C L U T C H - C L O S E

C 1 4 1 6 / 1

C 1 4 1 7 / 1

C L U T C H - P H - S E T

C 1 4 1 8 / 1

C 1 4 1 9 / 1

C L U T C H - O L - D E T

C 1 4 1 6 / 2

C 1 4 1 7 / 2

C L U T C H - P H - A C T

C 1 4 1 8 / 2

C 1 4 1 9 / 2

C T R L

C 1 4 1 2 / 3

C L U T C H - O L

C L U T C H - O P E N

C L U T C H

C 1 4 1 0

C 1 4 1 1 / 1
C 1 4 1 2 / 1
C 1 4 1 2 / 2

C L U T C H - O - P O S

C 1 4 1 3 / 1

Fig. 3−58

Virtual clutch (CLUTCH1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

CLUTCH1−MLIM

a

1415/1

dec [%]

1414/1

1

Threshold for "overload" monitoring

CLUTCH1−MACT

a

1415/2

dec [%]

1414/2

1

Act. value for "overload" monitoring

CLUTCH1−CLOSE

d

1417/1

bin

1416/1

2

HIGH: Close clutch
LOW: Open clutch

CLUTCH1−OL−DET

d

1417/2

bin

1416/2

2

HIGH: Activate overload monitoring

CLUTCH1−PHI−SET

ph

1419/1

inc

1418/1

3

Set drive position

CLUTCH1−PHI−ACT

ph

1419/2

inc

1418/2

3

Actual drive position

CLUTCH1 −OPEN

d

1

HIGH: Clutch open

CLUTCH1−OL

d

1

HIGH: overload monitoring has responded

CLUTCH1−O−POS

ph

3

Position, in which the clutch has been disengaged (65536 inc =
1 motor rev.)

CLUTCH1−NSET

phd

4

Speed setpoint for:

·

Brake drive after command OPEN

·

Set drive to target position

·

Set drive to open−position

Function

l

Overload monitoring (chapter. 3.2.22.1)

l

Disengage clutch (chapter 3.2.22.2)

l

Engage clutch (chapter 3.2.22.3)

This manual is related to the following products: