Clear radius – 3Com WXR100 3CRWXR10095A User Manual
Page 626

626
C
HAPTER
16: RADIUS
AND
S
ERVER
G
ROUP
C
OMMANDS
clear radius
Resets parameters that were globally configured for RADIUS servers to
their default values.
Syntax —
clear radius {deadtime | key | retransmit |
timeout
}
deadtime
— Number of minutes to wait after declaring an
unresponsive RADIUS server unavailable before retrying the RADIUS
server.
key
— Password (shared secret key) used to authenticate to the
RADIUS server.
retransmit
— Number of transmission attempts made before
declaring an unresponsive RADIUS server unavailable.
timeout
— Number of seconds to wait for the RADIUS server to
respond before retransmitting.
Defaults — Global RADIUS parameters have the following default
values:
deadtime—0 (zero) minutes (The WX switch does not designate
unresponsive RADIUS servers as unavailable.)
key—No key
retransmit—3 (the total number of attempts, including the first
attempt)
timeout—5 seconds
Access — Enabled.
History —Introduced in MSS Version 3.0.
Usage — To override the globally set values on a particular RADIUS
server, use the set radius server command.
Examples — To reset all global RADIUS parameters to their factory
defaults, type the following commands:
WX4400# clear radius deadtime
success: change accepted.
WX4400# clear radius key
success: change accepted.
WX4400# clear radius retransmit
success: change accepted.