Set fdb agingtime – 3Com WXR100 3CRWXR10095A User Manual
Page 170

170
C
HAPTER
5: VLAN C
OMMANDS
See Also
set fdb agingtime
Changes the aging timeout period for dynamic entries in the forwarding
database.
Syntax —
set fdb agingtime
vlan-id age seconds
vlan-id
— VLAN name or number. The timeout period change
applies only to entries that match the specified VLAN.
age
seconds
— Value for the timeout period, in seconds. You can
specify a value from 0 through 1,000,000. If you change the timeout
period to 0, aging is disabled.
Defaults — The aging timeout period is 300 seconds (5 minutes).
Access — Enabled.
History —Introduced in MSS Version 3.0.
Examples — The following command changes the aging timeout period
to 600 seconds for entries that match VLAN orange:
WX4400# set fdb agingtime orange age 600
success: change accepted.