AltiGen MAXCS 7.0 Update 1 ACM Administration User Manual
Page 62
Chapter 4: System Configuration
46
MaxCS 7.5 Administration Manual
Figure 12.
System Configuration, General tab
You can set the following parameters and options:
Parameter
Description
System ID
Assign a number (1-100) to the system. This ID will be used to
differentiate call records if multiple systems are writing call records to a
same external database.
In a multi-site VoIP domain, each System ID/Server ID must be unique
and must be the same length. Once a server is part of a VoIP domain,
you cannot change the System ID.
Country
Select a country for the system. This configuration ties to a tone table
matched to the country's telecom interface specification.
Manager Extension
Select the system manager’s extension number.
The system manager has access to the following system administrator
functions:
•
Record custom phrases
•
Turn on trunk blocking (#38)
•
Manage voice mail’s System Distribution List from phone
•
Run CDR search as administrator login account
Distinctive Ring
Enables users to distinguish between internal, external, and operator
calls by the way the phone rings:
•
Enable Distinctive Ring
– establishes a short double ring cadence
for internal calls and a normal, single ring for external calls. When
disabled, both rings are normal.
•
Enable Operator Priority Ringing
– produces a long single ring
between short pauses on calls to the operator.
•
Enable Workgroup Priority Ringing
– produces a short single
ring between short pauses on calls to the workgroup.