AltiGen MAXCS 7.0 Update 1 ACM Administration User Manual
Page 417
MaxCS 7.5 Administration Manual 401
Colombia MFC-R2
Set calling part category
: 2
[Assume no caller ID provided]:
Incoming sequence
: DID/DNIS
In-call signaling
(depend on how many DID digits):
For 3-digit DID, set to (113)6
For 4-digit DID, set to (1113)6
For 5-digit DID, set to (11113)6
For 6-digit DID, set to (111113)6
For 7-digit DID, set to (1111113)6
For 8-digit DID, set to (11111113)6
[Assume caller ID provided]:
Incoming sequence
(same as above shown):
DID/DNIS * Caller ID
In-call signaling
(depend on how many DID digits):
For 3-digit DID, set to (115)*(K)36
For 4-digit DID, set to (1115)*(K)36
For 5-digit DID, set to (11115)*(K)36
For 6-digit DID, set to (111115)*(K)36
For 7-digit DID, set to (1111115)*(K)36
For 8-digit DID, set to (11111115)*(K)36
Ecuador MFC-R2
Set calling part category
: 1
[Assume no caller ID provided]:
Incoming sequence
: DID/DNIS
In-call signaling
(depend on how many DID digits):
For 3-digit DID, set to (113)6
For 4-digit DID, set to (1113)6
For 5-digit DID, set to (11113)6
For 6-digit DID, set to (111113)6
For 7-digit DID, set to (1111113)6
For 8-digit DID, set to (11111113)6
[Assume caller ID provided]:
Incoming sequence
(same as above shown):
DID/DNIS * Caller ID
In-call signaling
(depend on how many DID digits):
For 3-digit DID, set to (115)*(K)36
For 4-digit DID, set to (1115)*(K)36
For 5-digit DID, set to (11115)*(K)36
For 6-digit DID, set to (111115)*(K)36
For 7-digit DID, set to (1111115)*(K)36
For 8-digit DID, set to (11111115)*(K)36
Country