AltiGen MAXCS 7.0 Update 1 ACM Administration User Manual
Page 164
Chapter 12: Trunk Configuration
148
MaxCS 7.5 Administration Manual
Following are the parameters for the Triton T1 Configuration dialog box.
Parameter
Description
T1 robbed-bit signaling
Protocol
You can set Protocol to one of the following:
•
E&M Wink Start (default)
•
E&M Immediate Start
•
Ground Start
•
Loop Start
For signaling from one board to another, only E&M Wink Start is supported. Loop
Start, Ground Start, and E&M Immediate Start protocols cannot be used for
interfacing between two boards.
Dialing Delay
Specifies the delay, in milliseconds, after trunk seizure and before digit dialing.
This configuration will slow down the system transmitting digits to the CO by a de-
fined delay to avoid missing digits. Do not change this value unless advised.
Caller ID and DID Collection
You can select the maximum time-out delays, in seconds, and the appropriate sequence of symbols to be
collected for Caller ID and DID.
Max. seconds before
the first digit
Maximum wait time before time-out for the system to identify this digit after either
the first ring in ground start or loop start or the wink in wink start. The range is from
1-6 seconds, or None, with a default value of 3 seconds. Do not change this value
unless advised.
None
means no Caller ID or DID information will be collected. All other options
will be grayed out. Use this option to disable Caller ID and DID collection.
Max. seconds
between digits
Maximum wait time before time-out between two digits. Default value is None. Do
not
change this value unless advised.
Selecting None means the system will only wait for the sequence of digits that are
collected within the length of time specified in the Max. seconds before the first
digit field.
Incoming sequence
Select up to five incoming symbols to collect from the Caller ID or DID digits:
•
None
•
#
•
*
•
# or *
•
Caller ID
•
DID/DNIS
Selecting None in any field of the sequence will terminate the sequence and
automatically disable subsequent entries in the sequence.
The default sequence is:
“# or *” (and then) “Caller ID” (and then) “# or *” (and then) “DID/DNIS”
Or
Sets up an additional, alternative sequence. You can select another set of up to
five incoming symbols to collect.
Not checking any box is equivalent to checking None in the first field.
The default sequence is:
“DID/DNIS”
Apply to
If appropriate, you can use this button, as described in “Configuring One or
Multiple Trunks” on page 139, to apply the Caller ID Collection to multiple T1
trunks.
Note:
In order for back-to-back T1 and tie trunk T1 configurations to perform properly, it is recommended
that you use the system’s default incoming call sequences: