Chapter 30: Tools and Applications

376

MaxCS 7.5 Administration Manual

CT-Bus Test Tool

The CT-Bus Test Tool is a tool that detects one-way connection, cross talk, bad MVIP cable and static noise
problems.
To run the CT-Bus test tool,
1.

Stop AltiGen Switching Services before running this utility.

2.

Launch CT-Bus Test Tool from Start > All Programs > MAXCS > Gateway Tools > CT-Bus Test Tool.

3.

Click Start to begin the test.

4.

At the end of the test, the utility provides pass or fail results.

Backup and Restore Utility

Note:

The configuration backup option is turned on by default.

Backups do not include CDRs.
To back up or restore data, select either

From MaxAdmin: Services > Utilities > Backup and Restore, or

From the Windows Start menu: All Programs > MAXCS > Utilities > MAXCS ACC/ACM Backup and
Restore.

Figure 221.

Backup and Restore window

Note:

The Backup and Restore window can only be accessed at the primary MAXCS system; it is not
available from a remote MaxAdmin client.

Backing Up Files

Note:

The AltiGen backup utility does not back up internal CDR database. You must back up the internal
CDR database from \AltiDB\InternalDB\Internal.mdb manually.