Configure traps:
•
Memory usage exceeds
– This trap is sent when MAXCS detects that the lowest virtual memory usage
exceeds a specified percentage of physical memory configuration within a 10-minute duration. Default val-
ue is 80%. The next trap will be sent after the condition is cleared then occurs again. The minimum dura-
tion between any two consecutive traps is 30 minutes
•
Average CPU utilization exceeds
– This trap is sent when MAXCS detects its average CPU utilization
exceeds a specified percentage in any 10-minute duration. Default value is 80%. The next trap will be sent
after the condition is cleared then occurs again. The minimum duration between any two consecutive traps
is 30 minutes
•
Hard disk usage exceeds
– This trap is sent when hard disk usage of MAXCS transitioning from below
threshold to on or above threshold is detected. Default value is 80%. The minimum duration between any
two consecutive traps is 30 minutes.
List of Traps Sent
A trap is sent when the following conditions are detected.
•
Cold Start (generic trap). When AltiServ is cold started and initialized successfully.
•
Warm Start (generic trap). When AltiKeep service detects AltiServ.exe is down, re-starting AltiServ.exe,
and AltiServ is initialized successfully.
•
LinkDown (generic trap). When detecting a T1/E1/PRI span state is transitioning from up to down or losing
clock source.
When a gateway is down, one trap is sent for each T1/E1/PRI interface in this Gateway. This trap is sent
when SIP trunk destination state transitioning from reachable to unreachable is detected.
Every T1/E1/PRI span and SIP trunk channel is assigned a unique "ifIndex" value as a port identifier
•
LinkUp (generic trap). When a T1/E1/PRI span state transitioning from down to up is detected.