AltiGen MAXCS 7.0 Update 1 ACM Administration User Manual
Page 136
Chapter 11: Board Configuration
120
MaxCS 7.5 Administration Manual
Figure 69.
T1 PRI Switch Mode
The top four settings are used for a connection to a CO switch:
•
AT&T 4ESS PRI
•
AT&T 5ESS PRI
•
NT DMS-100 PRI
•
NI-2 PRI (default)
The bottom four settings are used for a PRI tie trunk configuration where two MAXCS systems are connected
back to back. In such a configuration, one MAXCS system must be configured as Network and the other as
User. For example, set one to NI-2 PRI Network and the other to NI-2 PRI.
•
AT&T 4ESS PRI Network
•
AT&T 5ESS PRI Network
•
NT DMS-100 PRI Network
•
NI-2 PRI Network
If you select a Span Type of Regular ISDN PRI in the E1 PRI Configuration window, use the following
guidelines to set the ISDN PRI Switch mode.