Type of registered services provided, Service order code, T1 channel assignment – AltiGen MAXCS 7.0 Update 1 ACM Administration User Manual
Page 428: Csu/dsu requirements, Service parameters/request information for pri

Appendix B: Required Service Parameters
412
MaxCS 7.5 Administration Manual
DNIS, Caller ID:
•
DTMF (Dual Tone Multi-Frequency)
Physical Termination:
•
RJ-48X or RJ-48C
Wire:
•
4 wires
800 Service:
•
You decide
Termination Impedance:
•
100 ohms
Type of Registered Services Provided
•
BN 1.544 Mbps SF without power
•
DN 1.544 Mbps SF B8ZS without power
•
1KN 1.544 Mbps ANSI ESF without power
•
1SN 1.544 Mbps ANSI ESF, B8ZS without power (recommended)
Service Order Code
SOC 6.0P AS.2
T1 Channel Assignment
•
Trunk Type – In, Out, or 2-Way (recommended)
•
Channels Assigned – 24 (Enter partial channels if you wish to subscribe to both voice and data service.)
•
Hunting – Most Idle, Least Idle, Ascend, Descend
•
DNIS Digits/Signal – 3/DTMF (can be 3 to 10 digits)
•
Caller ID Signal – DTMF, if available (Not every service provider provides Caller ID over T1 lines.)
CSU/DSU Requirements
The CSU (channel service unit) is a device used to connect a digital trunk line coming in from the phone
company to the PBX. A CSU can terminate signals, repeat signals and respond to loopback commands sent
from the central office.
Service Parameters/Request Information for PRI
To subscribe to PRI service, certain parameters are required to establish service. The information provided
below identifies the recommended and supported parameters for PRI service. When ordering PRI service, pro-
vide the following service request information:
Equipment Information
•
PBX Manufacturer – AltiGen Communications, Inc.
•
CSU/DSU – ADTRAN T1 ACE (recommended) or other CSU/DSU