Appendix A: E1-R2 and E1 ISDN PRI Installations
406
MaxCS 7.5 Administration Manual
Mexico / Teléfonos de
Mexico
Set calling part category
: 2
[Assume no caller ID provided] :
Incoming sequence
: DID/DNIS
In-call signaling
(depend on how many DID digits):
For 3-digit DID, set to (113)1
For 4-digit DID, set to (1113)1
For 5-digit DID, set to (11113)1
For 6-digit DID, set to (111113)1
For 7-digit DID, set to (1111113)1
For 8-digit DID, set to (11111113)1
[Assume caller ID provided]:
Incoming sequence
(same as above shown):
DID/DNIS * Caller ID
In-call signaling
(depend on how many DID digits):
For 3-digit DID, set to (116)*(K)31
For 4-digit DID, set to (1116)*(K)31
For 5-digit DID, set to (11116)*(K)31
For 6-digit DID, set to (111116)*(K)31
For 7-digit DID, set to (1111116)*(K)31
For 8-digit DID, set to (11111116)*(K)31
Panamá / Nacional MFC-
R2
Set calling part category
: 1
[Assume no caller ID provided]:
Incoming sequence
: DID/DNIS
In-call signaling
(depend on how many DID digits) :
For 3-digit DID, set to (113)6
For 4-digit DID, set to (1113)6
For 5-digit DID, set to (11113)6
For 6-digit DID, set to (111113)6
For 7-digit DID, set to (1111113)6
For 8-digit DID, set to (11111113)6
[Assume caller ID provided]:
Incoming sequence
(same as above shown):
DID/DNIS * Caller ID
In-call signaling
(depend on how many DID digits):
For 3-digit DID, set to (115)*(K)36
For 4-digit DID, set to (1115)*(K)36
For 5-digit DID, set to (11115)*(K)36
For 6-digit DID, set to (111115)*(K)36
For 7-digit DID, set to (1111115)*(K)36
For 8-digit DID, set to (11111115)*(K)36
Country