E1 pri, Configuring an isdn numbering plan – AltiGen MAXCS 7.0 Update 1 ACM Administration User Manual
Page 137
Configuring the Triton T1/E1 Board
MaxCS 7.5 Administration Manual 121
E1 PRI
Figure 70.
E1 PRI Switch Mode
The top three settings are used for a connection to a CO switch:
•
Austel TS014 PRI
•
ETSI NET5PRI
•
NT DMS-100 PRI
The bottom three settings are used for a PRI tie trunk configuration where two MAXCS systems are connected
back to back. In such a configuration, one MAXCS system must be configured as Network and the other as
User. For example, set one to NT DMS-100 PRI Network and the other to NT DMS-100 PRI.
•
Austel TS014 PRI Network
•
ETSI NET5PRI Network
•
NT DMS-100 PRI Network
Configuring an ISDN Numbering Plan
The ISDN Numbering Plan button in the Protocol Configuration window opens the PRI ISDN Numbering
Plan
dialog box. This function allows you to select how the system will identify and code the Called Number
for six different types of calls. This coding instructs the CO on how to interpret the number being sent to it.