Setting thresholds
The system predefines four traffic alarm thresholds. They are thresholds of SA incoming traffic, SA
outgoing traffic, SA incoming bandwidth utilization, and SA outgoing bandwidth utilization. You can
modify but cannot add or delete the thresholds.
Viewing default threshold list
1.
Click the Service tab.
2.
From the navigation tree, select MPLS VPN Manager > Traffic Monitor > Threshold Setting.
The Threshold Setting page appears.
Default Threshold List contents
{
Name—Name of the threshold.
{
Level-1 Alarm Status—Whether the level-1 alarm for the threshold is Enabled or Disabled.
{
Level-1 Alarm Threshold—If the level-1 alarm is enabled, this field displays the threshold. If the
level-1 alarm is disabled, this field displays hyphens (--).
{
Level-1 Alarm Severity—Critical, Major, Minor, Warning, or Info.
{
Level-2 Alarm Status—Whether the level-2 alarm for the threshold is Enabled or Disabled.
{
Level-2 Alarm Threshold—If the level-2 alarm is enabled, this field displays the threshold. If the
level-2 alarm is disabled, this field displays hyphens (--).
{
Level-2 Alarm Severity—Critical, Major, Minor, Warning, or Info.
{
Modify—Click the Modify icon
to enter the page for modifying the threshold.
3.
Click Refresh to view the latest Default Threshold List.
Modifying SA inbound/outbound traffic thresholds
1.
Click the Service tab.
2.
From the navigation tree, select MPLS VPN Manager > Traffic Monitor > Threshold Setting.
The Threshold Setting page appears.
3.
Click the Modify icon
for SA Incoming Traffic (bytes/s) or that for SA Outgoing Traffic
(bytes/s).
The page for modifying the threshold appears.
4.
Enable Enable level-1 alarm. Enter a value in bytes/s in the When the value is greater than field,
and select an alarm severity from the list between Send and Alarm. Options for the alarm severity
include Critical, Major, Minor, Warning, and Info.
5.
Enable Enable level-2 alarm. Enter a value in bytes/s in the When the value is greater than field,
and select an alarm severity from the list between Send and Alarm. Options for the alarm severity
include Critical, Major, Minor, Warning, and Info.