Querying devices, Synchronizing devices – H3C Technologies H3C Intelligent Management Center User Manual
Page 238

3.
Click the Delete Devices button in the upper-left corner of the Device List.
Querying devices
To query a device from the MPLS management:
1.
Click Service > MPLS Management > Device Management from the tabular navigation system on
the top of the IMC main page.
2.
Enter searching conditions in the Query Devices pane:
•
Device Name—Indicates the device names or IP addresses.
•
Device Status—Indicates the device status. Values include All, Unmanaged, Unknown,
Normal, Warning, Minor, Major, and Critical. Device Status is determined by the highest
severity or alarm level for the device when a device has more than one current alarm that has
not been cleared or recovered. Devices that are added to but not managed by IMC are
categorized as unmanaged. Devices whose information cannot be obtained by IMC are
categorized as unknown.
•
MPLS LDP Status—Indicates the MPLS LDP status. Values include: All, Enabled and Disabled.
•
LSR ID—Indicates the LSR ID.
•
MPLS Status—Indicates the MPLS status. Values include: All, Enabled and Disabled.
3.
Click the Query Devices button. The Device List displays all the devices that match the searching
conditions. Click the Reset button to clear the searching conditions.
NOTE:
The Device Name and LSR ID fields support fuzzy match.
Synchronizing devices
The synchronization function enables the system to obtain configuration information from the specified
devices immediately, and to manage the device information in MPLS management. You can determine
whether the current device configuration is valid by checking the last synchronization time and
synchronization status of the device.
To synchronize one or more devices from the MPLS management:
1.
Click Service > MPLS Management > Device Management from the tabular navigation system on
the top of the IMC main page.
2.
Select one or more devices to be synchronized.
3.
Click the Synchronize button in the upper-left corner of the Device List.
NOTE:
•
The synchronization process may take a while. You may need to click the Refresh button to display the latest
synchronization status.
•
Do not synchronize devices when adding LSPs. Synchronize devices before you add LSPs to avoid possible
errors.
228