c.
Select Static CR-LSP from the Protocol list.
d.
Enter the loopback address of the egress device in the field of Destination IP Address (A.B.C.D),
and then click Next.
5.
In the Configure Static CR-LSP page, click Add.
The Add Static CR-LSP Node screen with Ingress selected as the role appears, as shown in
.
Figure 44 Add Static CR-LSP Node screen with Ingress selected as the role
6.
Add an ingress device node.
a.
Click Select next to Select Device. In the Select Device page, specify part or the entire name of
the ingress device, and then click Query. Devices that match the description appear in the
Device Query List section of the page. Select the ingress device, and then click OK.
b.
Select Ingress from the Select Role list.
c.
In the Destination Address (A.B.C.D) field, enter the loopback address of the egress device.
d.
In the Next Hop (A.B.C.D) field, enter the IP address of your next hop.
e.
Next to Out Label, enter the out label value, and then click Detect to see if this value is
available.
f.
Click OK. The information of the ingress device appears in the Configure Static CR-LSP section
of the page.
7.
Add a transit device node.
a.
In the Configure Static CR-LSP section of the page, click Add.
The Add Static CR-LSP Node screen with Transit selected as the role appears, as shown
in
.
165