Options – Keri Systems Doors.NET Manual User Manual
Page 339
Doors.NET Reference Manual
- 339 -
l
Poll Delay (ms)
- the delay between communication polls (in milliseconds)
l
Retry Count
- the number of retries before a communication failure is reported
l
Offline Timeout (ms)
- the amount of time in milliseconds for the controller to con-
sider itself offline with the host
l
Baud Rate to Panels
- the baud rate to the downstream field devices
Communications Interface
l
Enable Communications
- lists if communications to this panel are enabled
l
Bus
- lists the bus number to which this panel is connected
Monitoring
l
Device Type
- select a device type identifier which is used in event monitoring, sort-
ing, and operator assignments
l
Primary Priority
- the priority for this object. The range is 0 to 255 with 0 being the
highest priority.
l
Use This Filter
- select a custom filter which controls which events are displayed,
acknowledged, or recorded (in the case of event video recording)
l
Require Acknowledgement
- Enables Operator acknowledgement for this object.
The type of event(s) to be acknowledged is determined by the filter.
l
Enable Sounds
- enables Sound alerts for this object. The sounds are played as a
result of the state of an alert and are configured through the Device Types.
l
Global Trigger
- select an event trigger that will be tested when this panel creates
an event - if the event matches the trigger, the trigger will activate
Options
l
Download Cardholders with no Access Rights
- This option downloads each card-
holder regardless of access rights. Otherwise, only cardholders that have access
rights to a door on this controller are sent
l
Enable Area Control
- This option enables area control on this controller. Area Con-
trol allows doors to be grouped together for counting or Global Anti-Passback pur-
poses.