Keri Systems Doors.NET Manual User Manual
Page 29

Doors.NET Reference Manual
- 29 -
l
Added the ability to set operator permissions for viewing the status menu. Pre-
viously, all operators could view the status menu; now permission can be either
granted or denied per operator.
l
Corrected an issue that prevented Panel type hardware Reports from being gen-
erated.
Unique to NXT Controllers:
l
Extended the maximum strike time. The program had been limiting the maximum
strike time to 255 seconds; this is much too short a time. It now allows a strike time
of up to 65535 seconds (1092 minutes or 18 hours).
l
Corrected an issue where an incorrect door status was reported when doors were
in lockout mode. Enhanced to show effective Card Only or Card And PIN mode
based on both dual verification time schedule and requested dual verification
mode.
l
Update Network corrected to send full configuration to controller. Was sending only
a partial configuration to controllers while only Auto Config would send a full con-
figuration.
Unique to PXL Controllers:
l
Corrected an issue if an alarm sound was programmed to play when a controller
offline event occurred, the alarm sound would not play.
l
Corrected an issue with the PXL gateway. When it was manually stopped, events
occurring during the stoppage period were not being correctly retrieved from the
controller and passed up to the program.
l
Corrected an issue with the PXL gateway. If you disable a controller and then re-
enable that controller, you had to restart the gateway to bring the controller back
online.
l
Added support for Global Lock types Lock, Lockout, and Lockdown.
Unique to Keri NXT Mercury Powered Controllers:
l
Now limits firmware upgrade revisions displayed to those by hardware type. Pre-
viously all available firmware upgrades, regardless of hardware type, were dis-
played.
l
Added NXT Exit Readers to the pull-down list of available NXT reader models.
Now when adding a paired set of entrance/exit readers the program automatically
sets the entrance reader to Master paired with the exit reader. If you remove the
exit reader, then it will set the reader status back to single, and not paired.
l
Added several low-battery notification events for the ASSA Aperio product.
l
Corrected an issue if a controller was set to have a unique Controller Holiday
schedule, that schedule would be overridden by an update to the Master Holiday
schedule.