Known issues, Firmware requirements – Keri Systems Doors.NET Manual User Manual
Page 17
Doors.NET Reference Manual
- 17 -
l
Corrected an issue with event display filtering.
l
Implemented new WiFi/POE drivers provided by ASSA. Driver version is now 4.4.
NOTE: If you are upgrading an existing ASSA WiFi/POE installation you must manually
remove the existing ASSA driver (version 1.2) before running the Doors.NET installer.
Unique to IR/Schlage Hardware:
l
Corrected the display of the Interior Push Button indicator.
l
Corrected temp LED commands.
l
Corrected operation in Card OR PIN mode.
l
Now actively requesting Wake-on-Radio status, improving notification of latch state
changes.
l
Corrected a backwards compatibility issue for operation with older AD-series lock-
sets.
Known Issues
With NXT Controllers:
l
If additional doors are added to an existing access group, causing a cardholder in
that access group to exceed eight access levels, then Update Network will not
work for that controller. To correct this condition the operator will have to review
access group/door assignments and determine which assignment exceeds the
limit. This will be corrected in the next software release.
With PXL Controllers:
l
PXL controllers, by default, are configured for a standard credential file size.
Features such as Temp Cards, Anti Passback, Card + PIN, require a extended cre-
dential file size. Under most situations, the PXL gateway automatically notifies con-
trollers on the line that a switch to extended credential file size is required. This is
not being done correctly when Temp Cards is the feature being activated. The
workaround is to manually perform a full update to the controllers. This will be cor-
rected in the next software release.
Firmware Requirements
For NXT controllers and peripherals:
l
Standard NXT controllers require new firmware revision 2.05.40.
l
NXT Readers require firmware revision 3.00.01 or greater.
l
Reader Interface Modules (RIMs) require firmware revision 3.02.05 or greater.
l
4x4 I/O Modules require firmware revision 3.00.02.
For PXL: