Firmware Requirements

For NXT controllers and peripherals:

l

Standard NXT controllers require new firmware revision 2.05.25.

l

NXT Readers require current firmware revision 3.01.01.

l

Reader Interface Modules (RIMs) require current firmware revision 3.02.05.

l

4x4 I/O Modules require current firmware revision 3.00.02.

For PXL:

l

PXL controllers require current firmware revision 8.6.04

l

Legacy PXL controllers should be at firmware revision 8.4.49 or greater

NOTE: Legacy PXL controllers require the PXL Gateway license to be used with Door-
s.NET software.

For Mercury Powered NXT controllers:

l

Mercury Powered NXT controllers require new firmware revision 1.175.

For Mercury Hardware controllers:

l

Mercury Hardware controllers require new firmware revision 1.173.

Firmware Upgrades

NXT Firmware v2.05.25

l

Addresses an issue where corrupted network data in flash is not recovered and the
NXT board is in a constant state of reset (the 485 LEDs flash in sync). This typ-
ically happens when a controller reset command is interrupted during the reset pro-
cess, corrupting the data in flash. To handle this possibility, a backup copy of the
controller's network data is now stored in a unique location. If the controller detects
a corrupted flash or has issues with the network data, it will retrieve the backup
data and restore the primary data after it verifies that the controller's MAC address
stored is a valid Keri MAC address. If the controller's MAC address is invalid it then
writes a default MAC address: 00-14-34-ff-ff-ff and sets the IP Address to
169.254.1.1 and Subnet Mask to 255.255.0.0 allowing the controller to be redis-
covered and reconfigured via an Auto-Config.

Mercury Powered NXT Firmware v1.175

l

Provides support for the new IPv6 standard.

l

Improves the controller's network response when an Ethernet cable is unplugged.

l

Improves the controller's ability to recover from large, rogue data packets.

l

Corrects several ASSA and Ingersoll/Rand WiFi lock set issues.

l

Adds SNMP capability.

l

Corrects a Reader LED issue where the green LED state did not properly follow
the strike time.