Firmware requirements, Firmware upgrades – Keri Systems Doors.NET Manual User Manual
Page 31
Doors.NET Reference Manual
- 31 -
Firmware Requirements
For NXT controllers and peripherals:
l
Standard NXT controllers require new firmware revision 2.05.25.
l
NXT Readers require current firmware revision 3.01.01.
l
Reader Interface Modules (RIMs) require current firmware revision 3.02.05.
l
4x4 I/O Modules require current firmware revision 3.00.02.
For PXL:
l
PXL controllers require current firmware revision 8.6.04
l
Legacy PXL controllers should be at firmware revision 8.4.49 or greater
NOTE: Legacy PXL controllers require the PXL Gateway license to be used with Door-
s.NET software.
For Mercury Powered NXT controllers:
l
Mercury Powered NXT controllers require new firmware revision 1.175.
For Mercury Hardware controllers:
l
Mercury Hardware controllers require new firmware revision 1.173.
Firmware Upgrades
NXT Firmware v2.05.25
l
Addresses an issue where corrupted network data in flash is not recovered and the
NXT board is in a constant state of reset (the 485 LEDs flash in sync). This typ-
ically happens when a controller reset command is interrupted during the reset pro-
cess, corrupting the data in flash. To handle this possibility, a backup copy of the
controller's network data is now stored in a unique location. If the controller detects
a corrupted flash or has issues with the network data, it will retrieve the backup
data and restore the primary data after it verifies that the controller's MAC address
stored is a valid Keri MAC address. If the controller's MAC address is invalid it then
writes a default MAC address: 00-14-34-ff-ff-ff and sets the IP Address to
169.254.1.1 and Subnet Mask to 255.255.0.0 allowing the controller to be redis-
covered and reconfigured via an Auto-Config.
Mercury Powered NXT Firmware v1.175
l
Provides support for the new IPv6 standard.
l
Improves the controller's network response when an Ethernet cable is unplugged.
l
Improves the controller's ability to recover from large, rogue data packets.
l
Corrects several ASSA and Ingersoll/Rand WiFi lock set issues.
l
Adds SNMP capability.
l
Corrects a Reader LED issue where the green LED state did not properly follow
the strike time.