- 321 -
l
Gateway - the gateway type/name for the controller to which the door is connected
l
Controller - the name assigned to the controller
l
Panel Description - the type of controller panel (by manufacturer and physical char-
acteristics)
l
Description - the names assigned to the individual doors on that controller
l
Security Level - the level of security needed for that door: Low, Medium, High
l
Door Type - the physical type of door: i.e., interior, exterior, gate, turnstile, etc.
l
Door Class - the classification assigned to the door, typically a department name or
area
l
Manufacturer Model - the manufacturer and model type of the reader controlling
that door
Review/Edit Door Configuration Parameters
The right pane of the
lists all information and configuration parameters for the door
selected in the left pane. If an item in the grid is grayed-out it is not changeable.
General
l
Description - enter a descriptive name for this door (128 characters max)
l
Enabled - enable or disable this door
l
Door Type - group this door by its physical type: interior, exterior, gate, turnstile,
etc.
l
Door Class - assign this door a classification, typically a department name or phys-
ical area
l
Security Level - assign this door a security level (Low, Medium, High) based on the
kind of security needed at that door; typically an exterior access door may have a
higher security level than an interior door separating an office area from a man-
ufacturing area
l
Manufacturer Model - identify the manufacturer and model type of that reader; cer-
tain reader types have special features that are enabled when that reader type is
identified in the grid
l
Serial Number - enter a reader serial number if desired
l
Dual Verification Schedule - set a schedule during which dual verification is
required
l
Second Credential Timeout - set a timeout value for dual verification such that the
second credential must be presented within that timeout period
l
Auto Unlock Schedule - set an
for the reader; a time
schedule that defines when that door should be automatically unlocked and then
relocked
l
First Person In - set an offset period of time to allow an early arriving credential
holder to gain access through a door that is on an Auto Unlock schedule
Door Contact